This dew point calculator turns air temperature and relative humidity into the dew point, in degrees Celsius and Fahrenheit, using the Magnus formula.

Dew point

Dew point (Celsius)
-
Dew point (Fahrenheit)
-
Temperature minus dew point
-
Actual vapor pressure
-

How to use the dew point calculator

  1. Type the air temperature and choose Celsius or Fahrenheit.
  2. Type the relative humidity as a percentage from above 0 up to 100, for example 50 for 50 percent.
  3. Read the dew point in both units. The difference between temperature and dew point and the actual vapor pressure are shown below it.

Dew point formula

The calculator uses the Magnus formula (also called the August-Roche-Magnus approximation). With temperature T in degrees Celsius and relative humidity RH in percent:

γ = ln(RH ÷ 100) + (a × T) ÷ (b + T) Dew point = (b × γ) ÷ (a − γ)

The constants are a = 17.625 and b = 243.04 °C. They come from the improved Magnus-form fit published by Alduchov and Eskridge: "Improved Magnus form approximation of saturation vapor pressure", Journal of Applied Meteorology, vol. 35, pp. 601–609, April 1996 (equation 21, over water), also available as a report on OSTI.gov. The same pair of constants is listed in the humidity formulas page of the University of Miami's Brian McNoldy. Alduchov and Eskridge give a relative error of less than 0.4 percent for saturation vapor pressure between -40 and 50 °C, which is why this calculator only accepts temperatures in that range. Source data checked November 2026.

For Fahrenheit input the calculator converts to Celsius with °C = (°F − 32) × 5/9, applies the formula, and converts the answer back.

Worked example 1: 20 °C and 50 percent humidity

γ = ln(0.50) + 17.625 × 20 ÷ (243.04 + 20) = −0.6931 + 1.3401 = 0.6470. Dew point = 243.04 × 0.6470 ÷ (17.625 − 0.6470) = about 9.3 °C (48.7 °F). Surfaces cooler than this would collect condensation.

Worked example 2: 86 °F and 70 percent humidity

86 °F is 30 °C. γ = ln(0.70) + 17.625 × 30 ÷ 273.04 = −0.3567 + 1.9366 = 1.5799, so the dew point is 243.04 × 1.5799 ÷ (17.625 − 1.5799) = about 23.9 °C, or 75.1 °F. The air is only about 6 degrees above the dew point, which is why it feels sticky.

What the dew point tells you

Limits

The result is an estimate from a published approximation, not a measurement. Humidity sensors have their own error, often a few percent of RH, and that error carries into the dew point. The formula is for dew (liquid water). Below freezing, the frost point differs slightly. Air pressure has only a small effect and is ignored here.

Frequently asked questions

What is the dew point?

The dew point is the temperature to which air must be cooled, at constant pressure and moisture content, for water vapor to start condensing into liquid. When the air temperature falls to the dew point, relative humidity reaches 100 percent and dew, fog or condensation can form.

Which formula does this dew point calculator use?

It uses the Magnus formula with the coefficients recommended by Alduchov and Eskridge (1996): a = 17.625 and b = 243.04 degrees C. First gamma = ln(RH / 100) + a x T / (b + T), then dew point = b x gamma / (a - gamma), with T in degrees C. Fahrenheit input is converted to Celsius first.

How accurate is the result?

The Magnus form with these coefficients is within about 0.4 percent of saturation vapor pressure between -40 and 50 degrees C, according to its authors. The calculator therefore accepts air temperatures from -40 to 50 degrees C (-40 to 122 degrees F). Real-world humidity sensors are usually less precise than the formula, so treat the result as accurate to about a degree at best.

What dew point feels humid or comfortable?

How people feel varies. As a rough guide, many people find a dew point below about 10 degrees C (50 degrees F) dry and comfortable, and feel the air becomes muggy once it rises above about 16 to 18 degrees C (60 to 65 degrees F). This is general information, not a health recommendation.

Why is the dew point lower than the air temperature?

Unless the air is fully saturated (100 percent relative humidity), it can still take in more water vapor, so it must be cooled before condensation starts. The gap between temperature and dew point shows how close the air is to saturation. A small gap means high relative humidity.